| Sign In | Join Free | My bjjsgy.com | 
 | 
Brand Name : GENY
Model Number : Automatic Test & Calibration line
Certification : ISO, CE
Place of Origin : China
MOQ : 1
Price : negotiate rates
Payment Terms : T/T, L/C, D/P, T/T
Supply Ability : 2 sets/ 3 months
Delivery Time : 6~8weeks
Packaging Details : Plywood cases
Voltage output short term deviation : ≤30(PPM)
Maximum voltage output power : 25(VA)
Voltage wave form distortion : <0.2%
Maximum current output power : 100(VA)
Model : YCSS-103
Accuracy class : Class 0.02
| Name of product | Three Phase Standard Power Source | 
| Model | YCSS-103 | 
| Accuracy class | Class 0.02 | 
| Main feature | Constructed by three sets of single phase multifunction standard AC power source, to output three phase voltage and three phase current signal. Suitable for calibrating Voltmeter, Ampere meter, Wattmeter, Energy meter. Etc. | 
| Voltage range (4 physical range) | 0~480(V) | 
| Voltage output accuracy | Class 0.02(50~400V) | 
| Resolution of output voltage | 1(mV) | 
| Minimum voltage adjustment value | 1(mV) | 
| Voltage output short term deviation | ≤30(PPM) | 
| Maximum voltage output power | 25(VA) | 
| Voltage wave form distortion | <0.2% | 
| Digit display on voltage | 6 digit | 
| Current range(6 physical range) | 0~120(A) | 
| Current output accuracy | Class 0.02(0.1~100A) | 
| Resolution of output current | 0.2(mA) | 
| Minimum voltage adjustment value | 0.2(mA) | 
| Current output short term deviation | ≤30(PPM) | 
| Maximum current output power | 100(VA) | 
| Current wave form distortion | <0.2% | 
| Digit display on current | 6 digit | 
| Phase position range | 0~360 ° | 
| Accuracy of phase position | 0.005 ° | 
| Resolution of phase position | 0.001 ° | 
| Minimum phase position | 0.001 ° | 
| adjustment value | |
| Digit display on phase position | 6 Digit | 
| Frequency range | 45~65(Hz) | 
| Output frequency | ≤0.01% | 
| accuracy(power frequency) | 
1. Functional Test
2. HV- High Voltage Test
3. IR- Insulation Resistance Test
4. Calibration
5. Starting Current Test
6. No-Load Test
7. Error at Lower Load Test
8. Error at Higher Load Test
9. Laser Printing
10. Chemical Sealing of the Meter Casing
11. Decision Stage.




*If you want to know more please check our official website:http://www.genymetertestequipment.com/
|   | 
| YCSS-103 Three Phase Automatic Test & Calibration Power Source Line Images | 
 High-Capacity Automated Metering CT Test System with Safe and Reliable Block
                                                                                        
                                                        
                        
                        
                        
                                                            High-Capacity Automated Metering CT Test System with Safe and Reliable Block
                                                    
                        
                     Single Phase Energy Meter Calibration Equipment For Single Energy Meter
                                                                                        
                                                        
                        
                        
                        
                                                            Single Phase Energy Meter Calibration Equipment For Single Energy Meter
                                                    
                        
                     Maximize Efficiency And Reliability Of EV Charging With Our Comprehensive Test
                                                                                        
                                                        
                        
                        
                        
                                                            Maximize Efficiency And Reliability Of EV Charging With Our Comprehensive Test
                                                    
                        
                     0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline
                                                                                        
                                                        
                        
                        
                        
                                                            0.05% Accuracy Polyphase Energy Meter Automatic Test Pipeline
                                                    
                        
                     YCSS-101 Single Phase Automatic Test & Calibration Power Source Line
                                                                                        
                                                        
                        
                        
                        
                                                            YCSS-101 Single Phase Automatic Test & Calibration Power Source Line
                                                    
                        
                     Single Phase Energy Meter Calibration Device For Mass Production
                                                                                        
                                                        
                        
                        
                        
                                                            Single Phase Energy Meter Calibration Device For Mass Production
                                                    
                        
                     Polyphase Energy Meter Automatic Test Pipeline 0.05% Accuracy Test Of Energy
                                                                                        
                                                        
                        
                        
                        
                                                            Polyphase Energy Meter Automatic Test Pipeline 0.05% Accuracy Test Of Energy
                                                    
                        
                     0.1% Accuracy Energy Meter Testing IEC 62053 Fully Automatic Ct For Metering
                                                                                        
                                                        
                        
                        
                        
                                                            0.1% Accuracy Energy Meter Testing IEC 62053 Fully Automatic Ct For Metering